LED Lighting For Sports Halls
Indoor Lighting that Can't be beaten
Contact Us Today To Discuss How Philips LED For Sports Could Help Your School
Philips offers the latest high-efficiency LED lighting for sports halls, providing a complete lighting solution with the PerfectPlay wireless control system with integrated LED floodlights, for all types of indoor sports and taking into account the requirements from the smallest through to the most complex indoor sports facility.
Optimise Operations
- Control The Lighting Easily - to provide light when and where.
- Streamline maintenance - with monitoring that shows outages throughout the facility
- Reduce energy consumption - with energy-efficient LED lighting, scheduling, and controls
Enhance experience
- Clear, uniform LED lighting increases comfort and well-being
- Improve visibility, safety, and comfort for athletes and spectators
- Create a unique ambience to complement various activities with flexible lighting
Improve Sustainability
- Reduce carbon footprint to support environmental initiatives
- Limit light pollution with advanced LED floodlight performance
- Increase the opportunity for sports with bright, energy-efficient LED lighting
Indoor Sports Lighting
Indoor Tennis Court Lighting
The objective is to ensure good visibility enabling both players and spectators to follow the progress of a game. The ball, regardless of its location and speed, should always be clearly visible. Creating good visibility requires sufficient contrast to be created between objects and their backgrounds, good illumination levels and even distribution of light across the playing surface (uniformity).
Multipurpose sports hall
Sports venues designed for multi-sports should ensure that their proposed led lighting for sports halls considers the needs of all the various sports to be played. Care must be taken to ensure that the lighting design produces uniformity of the required illumination, is adequately lit and that glare is minimized. The lighting should be positioned, so they do not hinder the players’ and officials’ vision.Indoor Swimming Pool Lighting
The main requirement is to ensure the safety of users by providing adequate illumination and control of reflection on the water surface. The control of surface reflection is particularly important to allow staff to deal with any swimmers in difficulty in the pool. With the complex nature of pool design and restrictions on positioning floodlights, it is important that lighting is considered at the earliest stages of the pool design.
Ice hockey lighting
The visibility of moving objects is dependent upon the angular size, speed and luminance of its background and the luminance of the surroundings. A high standard of lighting is required as the small, black and fast-moving puck has to be made to contrast against the ice rink so that the spectators and players can see it. This is especially true when there is a large distance between the ice and the spectators, such as in arenas or halls.As ice acts as a good diffuse reflector there should be no strong patterns of light that could distract from the game. Good lighting uniformity is important for seeing the puck.
Lighting A Sports Hall Indoor
Sports venues designed for multi-sports should ensure that their proposed lighting considers the needs of all the various sports to be played. Care must be taken to ensure that the lighting design produces uniformity of the required illumination, is adequately lit and that glare is minimized. The lighting should be positioned, so they do not hinder the players’ and officials’ vision. The specific visual requirements will depend on the activity. Most sports halls have to cater for a range of activities, and it may be necessary occasionally to accommodate different activities simultaneously in order to maximize use. It is normally necessary to design a general lighting scheme to cater for a wide range of activities and, if necessary, incorporate switching arrangements for different activities, levels of play or simultaneous multi-use. It is generally recommended that the lighting design be based on the requirements of the activity with the highest priority, while ensuring that, as far as practicable, all other potential activities are catered for.
Multipurpose hall Class I
EN12193: Eh ave > 750 lux OptiVision LED gen2
Specifications | OptiVision LED gen2 |
---|---|
Installation | 2 lines at 7m |
Floodlight | 12 x OptiVision LED gen2 643 W |
Floodlight Type | BVP515 IN T35 100K 1xLED950/757 A-MB/30 |
System Power | > 7.72 kW |
Eh ave | > 750 lux |
Emin/Eave | > > 0.7 |
Ra | >70 |
GR Max | 36.1 |
MF | 0.9 |
Multipurpose hall Class I
EN12193: Eh ave > 750 lux ClearFlood Large
Specifications | ClearFlood Large |
---|---|
Installation | 2 lines at 7m |
Floodlight | 20 x ClearFlood Large 549 W |
Floodlight Type | BVP651 1xECO65k/757 OFA52 |
System Power | 10.98 kW |
Eh ave | > 750 lux |
Emin/Eave | > 0.7 |
Ra | > 70 |
GR Max | 38.2 |
MF | 0.8 |
Multipurpose hall Class I
EN12193: Eh ave > 750 lux ClearFlood
Specifications | ClearFlood |
---|---|
Installation | 2 lines at 7m |
Floodlight | 44 x ClearFlood 244 W |
Floodlight Type | BVP650 G2 30K 1xECO/740 OFA52 |
System Power | > 10.7 kW |
Eh ave | >750 lux |
Emin/Eave | > >0.7 |
Ra | >70 |
GR Max | 35.6 |
MF | 0.8 |
Multipurpose hall Class I
EN12193: Eh ave > 750 lux
GentleSpace gen2(sports optic A)
Specifications | GentleSpace gen2 (sports optic A) |
---|---|
Installation | 2 lines at 7m |
Floodlight | 46 x GentleSpace gen2 200 W |
Floodlight Type | BY471P 1xLED250S/840 A50 GC |
System Power | 9.2 kW |
Eh ave | >750 lux |
Emin/Eave | > >0.7 |
Ra | >80 |
GR Max | 37.7 |
MF | 0.8 |
Multipurpose hall Class I
EN12193: Eh ave > 750 lux GentleSpace gen2
Specifications | GentleSpace gen2 |
---|---|
Installation | 2 lines at 7m |
Floodlight | 40 x GentleSpace gen2 200W |
Floodlight Type | BY471P 1xLED250S/840 WB GC |
System Power | 9.4 kW |
Eh ave | >750 Lux |
Emin/Eave | > >0.7 |
Ra | >80 |
GR Max | 37.7 |
MF | 0.8 |
Multipurpose hall Class II
EN12193: Eh ave > 500 lux ClearFlood Large
Specifications | ClearFlood Large |
---|---|
Installation | 2 lines at 7m |
Floodlight | 14 x ClearFlood Large 549 W |
Floodlight Type | BVP651 1xECO65k/757 OFA52 |
System Power | 7.69 kW |
Eh ave | >500 Lux |
Emin/Eave | > >0.7 |
Ra | >70 |
GR Max | 39 |
MF | 0.8 |
Multipurpose hall Class II
EN12193: Eh ave > 500 lux ClearFlood
Specifications | ClearFlood |
---|---|
Installation | 2 lines at 7m |
Floodlight | 30 x ClearFlood 244 W |
Floodlight Type | BVP650 G2 30K 1xECO/740 OFA52 |
System Power | 7.3 kW |
Eh ave | >500 Lux |
Emin/Eave | > >0.7 |
Ra | >70 |
GR Max | 34.7 |
MF | 0.8 |
Multipurpose hall Class II
EN12193: Eh ave > 500 lux
GentleSpace gen2 (sports optic A)
Specifications | GentleSpace gen2 (sports optic A) |
---|---|
Installation | 2 lines at 7m |
Floodlight | 30 x GentleSpace gen2 200 W |
Floodlight Type | BY471P 1xLED250S/840 A50 GC |
System Power | 6 kW |
Eh ave | >500 Lux |
Emin/Eave | > >0.7 |
Ra | >80 |
GR Max | 37 |
MF | 0.8 |
Multipurpose hall Class II
EN12193: Eh ave > 500 lux GentleSpace gen2
Specifications | GentleSpace gen2 |
---|---|
Installation | 2 lines at 7m |
Floodlight | 28 x GentleSpace gen2 200 W |
Floodlight Type | BY471P 1xLED250S/840 WB GC |
System Power | 6.6kW |
Eh ave | >500 Lux |
Emin/Eave | > >0.7 |
Ra | >80 |
GR Max | 21 |
MF | 0.8 |
Multipurpose hall Class III
EN12193: Eh ave > 200 lux ClearFlood
Specifications | ClearFlood Large |
---|---|
Installation | 2 lines at 7m |
Floodlight | 6 x ClearFlood Large 488 W |
Floodlight Type | BVP651 1xECO60k/757 OFA52 |
System Power | 2.93kW |
Eh ave | >200 Lux |
Emin/Eave | > >0.5 |
Ra | >70 |
GR Max | 40.3 |
MF | 0.8 |